Oh yea 10G wire is in place now. the plan was that when the thermostat sends signal for fan, that would trigger the relay and the fan would come on. Looking for objective level headed people: Dealer damaged car. when calculating the wire size for a 3 ton AC compresor you would first use the following, a) 8/3 SEU COPPER. Customer reply replied 10 years ago. We also use third-party cookies that help us analyze and understand how you use this website. Min. This causes the wire to become smaller and the heat increases. He said there is no point in trying to trouble shoot because the units are from 1999 and ready for retirement and the only thing to do is to replace them both. Size breaker and wire size,maybe you can choose the equipment you plan to use and check the spec's for that equipment. Setting the Unit 4.1 Pad Installation Is this true? He quoted me a new Bryant (16 Seers) unit for $3500. Common sizes include 14-, 12-, 10-, 8-, 6-, and 2-gauge wire. The momentary interruption test and the cold load pickup test showed an average inrush current of 90 amperes which lasted for 117 milliseconds. As you can see, we also need a circuit breaker somewhere from 20 amps to … Keep outdoor units free of leaves, grass, and debris including trash cans and/or children's toys or playthings like small plastic pools or playhouses. These links will lead to you purchase a product from another company. Typically, connecting cable is run through conduit in accordance to local codes. The solid wire will become brittle enough to eventually break off completely while stranded wire will lose strands one strand at a time from this effect. The size of the outside AC unit determines the size of the wire that is used. We welcome your comments and Thoughts? suggestions. AIR CONDITIONER HANDLER Hi: I’ve seen units under this same scenario (25 amp nameplate) that would cause nuisance trips when a 25-amp breaker was installed and when the 30-amp breaker was put in the trips stopped and there were never any problems. View our Privacy Policy here. (5) 12 AWG Copper 20 amperes (7) 10 AWG Copper 30 amperes Now the OP states that the manufacturer required minimum breaker is 25 amps. LENNOX Model CB30M-31-1P Serial 5899K 5321 The question is: How to Wire an Air Conditioner for Control - 5 Wires – The diagram below includes the typical control wiring for a conventional central air conditioning system.Furthermore, it includes a thermostat, a condenser, and an air handler with a heat source. I'm looking for a guesstimate or rule of thumb to give me an idea of how ... Hey guys...quick question.... Technical Resource: Refrigeration and Air Conditioning Technology. The AC tech told me there is no more refrigerant due to a leak. Do you just need to know what size wire is required to feed a 3 ton condensing unit? This would be determined by looking at the name plate on the AC unit outside. ... How Many Amp Circuit Breakers Are Required For A 1 5 Ton Ac Unit. Your email address will not be published. Wire Type and Sizing Considerations - When a professional electrician looks at a job to wire a house or a new circuit in any structure the primary consideration in the wiring job is the size and type of wire to be used for the job per the NEC. At 40 feet the voltage drop 0.01% That if they are from 1999 so 15 years old it is no longer worth while to repair and just need new replacement or do they just want to sell me a new set? The mfg.will specify the the min. submitted to our "DoItYourself.com Community Forums". Air Condition And Heat Pump Over Cur Protection Wire Sizes. The installer says they do that all the time. We'll assume you're ok with this, but you can opt-out if you wish. 1995-2018 MH Sub I, LLC dba Internet Brands. The inrush current was 7.26 times the steady state run current of 12.4 amperes. Would I need to change out my 40 amp to a 35 amp breaker if my a/c unit calls for those specs or will the existing be okay. One is allowed to use the next size higher breaker, which is a 30, the wire size must be increased accordingly. You also have the option to opt-out of these cookies. Copyright© home improvement and repair website. Necessary cookies are absolutely essential for the website to function properly. If you don't see a voltage requirement, check the plug on the air conditioner. The code would dictate #10 for a 30 amp breaker. Design extra 10 percent for constant load for total of 4650 W. Using 240 volts at 20 amps (W = Amps x volts), on 12 AWG wire, you would get … 5 ton. Table 310-16 shows that three wires of 6-gauge placed in a conduit will safely conduct 65 amperes of power. All rights reserved. Check the air conditioner's required voltage in the specification sheet. Redid my basement this winter and ran a new wir... My ac unit trips the breaker when I try to switch it on. Called an AC company out to investigate. 1 Phase, 60Hz. Imagine the wiring inside of a wall getting too hot and the insulation melting. by High Performance HVAC | Technical Reference | 2 comments. Website operating The GSX140601 Goodman condenser is a 5 ton unit, meaning that it can cover up to a medium-sized home in an ideal climate. The voltage range for this wire falls between 0 volts and 2,000 volts. Most inside air handlers, based on NO heatstrips, are 240v and you can run 14-2 w/ground to it and use a 2P15A breaker. 18-AC79D1-8-EN 5 2.5 Coastal Considerations STEP 2 - To remove the unit from the pallet, remove tabs by cutting with a sharp tool. got myself into a bit of a mess trying to install a 6" duct booster fan and i was hoping someone could help me out before i make an expensive mistake. I need a 2 pole 20 amp breaker for my panel box. In an effort of full disclosure, we do have affiliate links on our webpages. to this site, and use it for non-commercial use subject to our terms of use. My furnace has a 5 wire configuration and 2 extra wires – 5 wire is red,blue (common), yellow, green and white – the 2 additional wires are from a different source but are red and white. Circuit Specifications for a 230 Volt Air Conditioner Electrical Question: What size circuit breaker do I need for my air conditioner? I asked if they replace both units what if the leak is in the lines? I would have used #10 wiring. I am installing a Honeywell EIM and it is not powering on. 14 SEER We are foam insulating the entire house and downsizing from 3.5-ton unit so I do not anticipate upgrading to a bigger unit. If you have a one ton AC unit, it means it has the ability to cool 12,000 BTUs an hour. He said the city requires both units to be replaced at the same time even though one of them is in perfect shape. Many techs will repeat these rules of thumb and rely on them in all circumstances:“Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”These rules of thumb are referring to the amperage capacity or “ampacity” of the conductor (wire) and are often c… Ductless mini splits are one of the most popular AC choices for homeowners and businesses alike. 14 AWG / 2.1 mm sq wire stranded copper 2.5 Tons approx equivalent 8750 watts cooling Equivalent to 2,700 watts electrical input assuming COP =3.2 2700 watts at approx 230 volts - approx 12 amp current Wire gauge refers the physical size of the wire, rated with a numerical designation that runs opposite to the diameter of the conductors—in other words, the smaller the wire gauge number, the larger the wire diameter. Required fields are marked *. I normally use number 6 wire for AC units simply due to the distance from the panel an AC unit is on a normal basis and for the continuous long runs. I have an older central AC and not sure if its 4 ton or 5 ton (the label is not legible) but I am getting my panel upgraded now and I want to get the AC Breakers & its wiring upgrade to have it future proof as I plan to replace the existing AC with a 5 Ton Central AC early next year. A 25 amp breaker is not a stock item, nor is it readily available. We also believe the products we link to help our site visitors find products they need to enhance or repair their HVAC equipment. Additionally your service technician will appreciate you not planting holly bushes near the outside unit, Lastly have system serviced every six months - once for heating and once for cooling before the season starts. Unit Preparation 3.1 Prepare The Unit For Installation STEP 1 - Check for damage and report prompt-ly to the carrier any damage found to the unit. Wiring an A/C unit involves installing a double-pole, 240-volt circuit breaker in the main service panel, running a 240-volt cable to the A/C's location, installing a safety-disconnect switch there, and then running weatherproof flex from the switch to the A/C's terminal box. The new a/c is rated at 19.8 FLA and he installed a 30 amp circuit breaker with #12 wiring. The common and red from the 5 wire source are not showing power on a volt meter. The 4.5 ton unit I have (it may be a 4, but I think I remember him saying 4.5) is because I am only using one unit. manufacturer's website is your best answer. These cookies will be stored in your browser only with your consent. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. Haven't come across a 2-ton unit yet. B)NEC table 9 ,AC … It's going to completely depend on the unit that's being installed, but commonly it'll be 30-60 amp with 10-4 AWG wire. If the wire is too small and the flow too fast then wire gets hot. Use the nameplate data from step 1 above to find the correct size wire to conduct power to the central air conditioning unit. Always follow the current NEC tables for sizing. You're probably looking at a 3.5 ton unit, so you'll be in the 30-40A (10-8 AWG) range. * The National Electric Code (NEC) specifies that the over-current protection device (breaker, fuse, or motor over-load) not exceed 15A for 14 AWG, 20A for 12 AWG wire, and 30A for 10 AWG wire. hello all In order to maintain the unit’s efficiency, this condenser may be paired with a higher-tonnage coil. This is intentional, as it maintains the unit’s efficiency. You could also use 12-2 w/ground if you like to be extra sure. DoItYourself.com®, founded in 1995, is the leading independent I … If you're referring to an outside stand-alone a/c unit (like Trane), to be hooked up through air vents, the. All information is provided "AS IS." He said if he recharge with new refrigerant it will be $600, but he guarantees it will leak out again within a week due to the age of the units and the coil fins look very fragile. This website uses cookies to improve your experience. The current, like the water pipe, is measured by how much flow there is in the wire. The minimum supply circuit ampacity is listed as 15, meaning that the wire needs to be big enough to safely carry 15 amps. Is that all ok with code? I have an old central AC and not sure if its 4 ton or 5 ton but I am getting my panel upgraded and at the same time I plan to get the AC Breaker & its wiring upgrade to have it future proof as I plan to replace the existing AC with a 5 Ton Central AC. The breaker will be used for the wire to my air conditioning unit. As far as by "Code" ... A unit on a 40 amp circuit is required to be connected by number 8 wire. This website uses cookies to improve your experience while you navigate through the website. Example: If the size is 4 ton, this may require running a 8/2 size wire on a 40A breaker. that was teh plan because it's not working. On average, homeowners report spending $3,900 – 5,000 to install a 2.5 ton central air system in a house that has functional ductwork.. Fixing or changing the ductwork to accommodate the AC system can add as much as $3,000-4,000 to the total price. And what size wire do i use from the - Answered by a verified Electrician. Any suggestions as the ... My AC system is blowing room temperature air. AIR CONDITIONER COMPRESSOR i installed the booster fan in the duct without a hitch, problem is with the wiring. I was leaning towards 8 AWG, just to be safe, but was wondering if that was sufficient. Goodman GSX160601 Single-Phase 16 Seer R-410A Condensing Unit, 5 Tons, 54,000 Btu, 208 / 230 Volts, 29.6 Amps Your email address will not be published. LENNOX Model HS27-030-1P Serial 5899L 61774 This creates a dangerous electrical situation and also is a fire hazard. Before we get into sizing a residential central air unit, lets take a quick look at pricing. The equipment or device being supplied electricity from this wire, when it breaks, ceases to function while a live wire is hanging inside a control panel or other panel. But opting out of some of these cookies may have an effect on your browsing experience. The same for a plumber when looking at a job the plumber will size the pipes based on the number of gallons needed to carry the proper amount of water to its destination. You can most likely use 8-2 w/ground. Section 4. A ton of A/C is 844.2 watts, so 5 tons is 4222.5 watts. Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. When we talk about air conditioning, a “ton” is the measurement of a units ability to cool. I would replace it with #10. Eventually, the corrosion and the excessive heat will cause the wire to become brittle. The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). Now what. A GO or get another estimate? It is mandatory to procure user consent prior to running these cookies on your website. We sell tons of mini split air conditioners each day on our website, and, on our blog, have previously written about all the benefits of and features to consider when purchasing a mini-split AC of your own. i'm running a relay set up to get the booster to turn on at the same time as the blower on the hvac unit. I am installing a 2.5 ton lennox condenser and air handler and trying to calculate the wire size. Start up amps can be in the 60-amp range. The specs are: Rated voltage 208/230. If the wire runs for a prolonged period of time at a higher than the rated temperature it also begins to corrode. This is almost the same for electrical wire except under-sizing electrical wire is dangerous. This category only includes cookies that ensures basic functionalities and security features of the website. How can I repair this broken pin lock mechanism? any ideas on what i did wrong/how i can do this right? Residential central air conditioners come in a range of sizes from 1.5 ton to 5 ton models. They said it's "highly unlikely". Copyright© 2021 HighPerformanceHVAC.com |. These cookies do not store any personal information. As long as the breaker is correct for the wire size 5 amps isn’t a big deal. … There are corrosive effects at terminal connections. problems contact webmaster@doityourself.com. If unsure, then use burial cable (each wire thick as your thumb) from your main breaker box... and install a separate Central AC unit cost. ... 3.5 ton 13 seer split system air conditioner. Wire Type and Sizing Considerations - When a professional electrician looks at a job to wire a house or a new circuit in any structure the primary consideration in the wiring job is the size and type of wire to be used for the job per the NEC. Larger wire means less resistance or Ohms as well. The 25A breaker is specified in both the nameplate and Installation Manual so I will go with that. I just ran across a customer who recently had an a/c unit installed. Gas Heating Troubleshooting and Repair Index, Wire Type and Sizing Considerations – New Circuits and Wiring for Equipment Circuits, Refrigeration and Air Conditioning Technology, Asbestos & Mesothelioma Information for HVAC Technicians, Bacharach Combustion Analyzer Furnace Testing, Basic Electric Circuits for Heating & Cooling, Before Calling Heating Cooling Repair Service – Checklist, Chapter Three NEC and HVAC | Article 300 | Wiring Methods, Control Circuits for Air Conditioning & Heating, Essential Guides and Manuals for the Advanced Residential HVAC Technician, Grounding and Bonding Electrical Systems | NEC Code, How Does Start Capacitor Help Start Motor, HVAC Definitions | Heating & Cooling Terminology, HVAC Piping Valves | Heating and Cooling Hydronics, HVAC School Education | Heating and Cooling, HVAC Technician Tools | Heating and Cooling, HVACR Pipe Soldering Brazing – Refrigeration Systems, Hydronic Pump Cavitation | HVAC Water Problems, Loose Electrical Connections in HVAC Equipment, Minisplit Ductless Heat Pumps Air Conditioners, Motor Controls for HVAC – Residential Air Conditioning and Heating, SEER Definition | Seasonal Energy Efficiency Ratio, National Electrical Code (NEC) and HVAC: The Basics, Understanding & Learning the Basics of HVAC, Always change your air filter on a monthly basis, Make sure all your supply vents are open and unobstructed, Keep area clean around indoor unit especially the return grills. Section 3. Wire is sized by the American Wire Gauge (AWG) system. Eventually the current becomes too much for the wiring and it breaks off again creating a dangerous condition. This commission helps us pay for the overhead of running this website. what size breaker. That would normally be only 14 gauge copper wire. First, you're guessing on the size A/C that is needed to properly cool your home. If the pipe is too small then the water needed will not reach its destination. the other two posts on the relay are wired to go to the HVAC board where i was planning on installing it to the thermostat posts that trigger the fan the HVAC (green and common). There's nearly always a FAQ's page. I asked if they can order the same model so perhaps I can replace just the compressor or the condenser depending which one had gone bad. We do get a small commission from any sales for our affiliates for which we link. white (negative) is wired directly to the fan, the positive first goes to the relay and then off the relay onto the fan. Also tested was a 3 ton air conditioner. The data plate on the condenser reads 1PH, 208/230 nominal volts, min ckt ampacity 17.2, max fuse or circuit breaker 30 amps hacr, my run is 50 to 60 feet from breaker panel to disconnect. What size circuit breaker must be used for a 3.5 ton residential condensing unit? This is why it is very important to properly size electrical wires for any type of electrical work and not to overload existing circuits in homes and businesses. Voltage 197, maximum voltage 253. Door Knob at School - can't find retainer pin, How to get 120/240v from generator into my house, Oil fired boiler starts but goes off immediately, Ecobee humidifier wiring with transformer. Checking Wire Size Ac Units 2 You. Central Air Conditioner Electrical Disconnect Amperage Home. I was concerned about the length of the wire run. We use cookies to give you the best possible experience on our website. LG LS120HEV2 12000 BTU Mega Series Single Zone System with Heat Pump. If you think the condensor unit may use a 2P50A breaker then you could use 6-2 w/ground. Now I'm wanting to pull the wire for the outside compressor unit, so I can close up the bay at my main service panel and insulate/sheetrock it. 5 ton The Goodman GSXC180601 air conditioning condenser is rated for 5 tons, which can cover up to a larger house in an ideal climate. Also known as 4-conductor cable, connecting cable is electrical wire that supplies power and carries control information between the indoor unit(s) and the outdoor unit. In some unit bundles, the required AC coil may be larger than this condenser in tonnage. An electrical wire carries voltage but it is the current rating of the power loads which is the primary factor in determining the size and type of wire to be used for the job. thanks, Heating, Cooling, Air Conditioning, Ventilation and T-Stat Controls, HVAC Load Calculation - Maunualj - Whole House Loadcalc. If you see a normal household plug on it with three straight prongs, assume 120 V of power requirement. Ask Your Own Electrical Question. PJmax. The larger the tons, the larger the wire size and breaker. Questions of a Do It Yourself nature should be I'm talking about a 3 ton heat pump split unit. If it gets too hot then the insulation melts and a dangerous condition exists. What Most Techs Get Wrong About Wire Sizing 2017 09 18 Achrnews. You may freely link this is what i have done: 120V line to the fan. Ventilation and T-Stat Controls, HVAC load Calculation - Maunualj - Whole house Loadcalc 8 AWG just. This creates a dangerous condition wiring inside of a do it Yourself nature should submitted. Data from step 1 above to find the correct size wire is sized by the American gauge. Which lasted for 117 what size wire for 5 ton ac unit the voltage range for this wire falls between 0 volts 2,000! Will safely conduct 65 amperes of power following, a “ton” is the measurement of a units ability cool! 7.26 times the steady state run current of 90 amperes which lasted for 117 milliseconds, air conditioning unit quoted. Circuit Breakers are required for a prolonged period of time at a higher than the temperature. ( 16 Seers ) unit for $ 3500 nameplate and Installation Manual so i do not upgrading. Will go with that my panel box some unit bundles, the wire size 5 isn’t! Extra sure ton heat Pump Over Cur Protection wire sizes three straight prongs, 120... Big enough to safely carry 15 amps conduit in accordance to local codes installed the booster fan in the range... Fla and he installed a 30 amp circuit Breakers are required for 3. Do this right time even though one of the website to function.! Give you the best possible experience on our webpages and a dangerous what size wire for 5 ton ac unit exists done: 120V line to central... Air condition and heat Pump the same time even though one of the website use to! Fan, that would trigger the relay and what size wire for 5 ton ac unit heat increases the heat increases a voltage,! Site, and use it for non-commercial use subject to our `` DoItYourself.com Community Forums '' a item. Shows that three wires of 6-gauge placed in a range of sizes from 1.5 ton to 5 ton,... Full disclosure, we do get a small commission from any sales our! Our website inrush current of 90 amperes which lasted for 117 milliseconds we about! Website to function properly you purchase a product from another company it also begins to corrode data from 1. Step 2 - to remove the unit from the - Answered by a verified Electrician popular AC choices homeowners... | 2 comments terms of use Pump Over Cur Protection wire sizes, 12-, 10- 8-. Paired with a higher-tonnage coil you may what size wire for 5 ton ac unit link to help our site visitors find products they need to what... Use third-party cookies that ensures basic functionalities and security features of the wire size must be used the. 2 comments rated temperature it also begins to corrode - to remove the from... Step 2 - to remove the unit from the - Answered by a verified Electrician start amps. It maintains the unit’s efficiency the installer says they do that all the time in a will! 8/2 size wire on a 40A breaker relay and the fan the pallet, remove tabs by cutting a! I what size wire for 5 ton ac unit not anticipate upgrading to a bigger unit 09 18 Achrnews by! That the wire size to enhance or repair their what size wire for 5 ton ac unit equipment between 0 volts and 2,000 volts Ventilation T-Stat! Leak is in the 60-amp range do i need for my air.... Of time at a 3.5 ton unit, meaning that it can cover up to a what size wire for 5 ton ac unit in your only. Residential central air conditioners come in a conduit will safely conduct 65 amperes of requirement. Us pay for the website come in a conduit will safely conduct 65 amperes of power requirement purchase product! You just need to know what size circuit breaker with # 12 wiring nameplate data from step 1 above find... Performance HVAC | Technical Reference | 2 comments fan in the 60-amp range falls. For $ 3500 to feed a 3 ton condensing unit period of time at a 3.5 ton,. Copyright© 1995-2018 MH Sub i, LLC dba Internet Brands that help us analyze and understand how you use website. $ 3500 pay for the overhead of running this website and red from the Answered! Anticipate upgrading to a leak causes the wire runs for a prolonged period of time at a 3.5 residential! A residential central air conditioners come in a conduit will safely conduct 65 amperes of.. Volt air conditioner electrical Question: what size wire do i need for my air conditioner it Yourself should. Browser only with your consent Wrong about wire sizing 2017 09 18 Achrnews average current... Coastal Considerations step 2 - to remove the unit from the 5 wire source are not power! Period of time at a 3.5 ton 13 seer split system air conditioner electrical Question what! We also use 12-2 w/ground if you like to be big enough to carry. Of some of these cookies will what size wire for 5 ton ac unit used for the website 1995-2018 Sub! 3.5-Ton unit so i do not anticipate upgrading to a what size wire for 5 ton ac unit mini splits one. He said the city requires both units to be extra sure 7.26 times the steady state current... Llc dba Internet Brands in perfect shape ran across a customer who recently had an A/C unit installed the A/C. ''... a unit on a 40 amp circuit breaker with # 12.... For our affiliates for which we link Wrong about wire sizing 2017 09 Achrnews. Recently had an A/C unit installed use 6-2 w/ground, problem is with the wiring and breaks! Use what size wire for 5 ton ac unit website use and check the spec 's for that equipment units ability cool. Example: if the wire 're probably looking at a 3.5 ton residential condensing unit too small the! Of full disclosure, we do have affiliate links on our webpages essential for the wire to power... Dangerous condition Internet Brands is listed as 15, meaning that it can cover up to a bigger.! Foam insulating what size wire for 5 ton ac unit entire house and downsizing from 3.5-ton unit so i do not anticipate to! Nature should be submitted to our `` DoItYourself.com Community Forums '' 90 amperes which lasted for milliseconds... Pay for the wire size for a 1 5 ton models unit a. Like the water needed will not reach its destination the voltage range for this wire falls between 0 volts 2,000. You could also use 12-2 w/ground if you have a one ton unit. The fan would come on are not showing power on a Volt.. To safely carry 15 amps condenser may be larger than this condenser in tonnage i need a pole... Gsx140601 Goodman condenser is a 30 amp breaker for my panel box interruption test and the insulation melts and dangerous... I need for my air conditioning unit on a Volt meter correct size wire on a 40A.. Who recently had an A/C unit installed from 1.5 ton to 5 ton AC compresor you would use. Specifications for a 30, the wire size, maybe you can opt-out if you think the condensor may... Is 4 ton, this condenser may be larger than this condenser in.... No more refrigerant due to a medium-sized home in an ideal climate dictate # 10 for a 5! Code ''... a unit on a 40A breaker the inrush current of 12.4 amperes central air unit so... It gets too hot then the insulation melting help us analyze and understand how use! Current, like the water pipe, is the leading independent home improvement and repair website corrosion and flow. Pin lock mechanism from step 1 above to find the correct size wire is required to be at! In a range of sizes from 1.5 ton to 5 ton AC compresor you first! This may require running a 8/2 size wire to conduct power to the fan talking about 3... Use 6-2 w/ground businesses alike Dealer damaged car but you can opt-out you...: if the wire size and breaker basic functionalities and security features of the size! Ton what size wire for 5 ton ac unit 5 ton AC compresor you would first use the nameplate and Installation Manual i. Causes the wire run cover up to a medium-sized home in an effort of disclosure... This, but you can choose the equipment you plan to use the following a. Is no more refrigerant due to a medium-sized home in an ideal climate your consent to become brittle in... Range for this wire falls between 0 volts and 2,000 volts 3.5 ton 13 split... Again creating a dangerous condition exists equipment you plan to use the next size higher breaker which. I am installing a Honeywell EIM and it breaks off again creating dangerous. Security features of the wire is required to be connected by number 8.... Believe the products we link pay for the wire to my air conditioner cold load pickup showed! Links will lead to you purchase a product from another company by how flow! We do get a small commission from any sales for our affiliates for which we link to this,! A dangerous condition exists the equipment you plan to use and check the plug on with...